# Thermal gap and assembly clearance # Scope: Required free gap from uniform linear expansion plus tolerance. # Status: illustrative worked example; engineering review pending. # Inputs are example values. Checks are editable example requirements, not standards. length = 1 m coefficient = 0.000023 K^-1 rise = 60 K tolerance = 0.2 mm gap = 2 mm required := length*coefficient*rise+tolerance [mm] check gap sufficient: gap >= required scenario alternative: length = 0.8 m