# Heating time and energy # Scope: Lumped sensible heating; constant net power, losses omitted. # Status: illustrative worked example; engineering review pending. # Inputs are example values. Checks are editable example requirements, not standards. mass = 1 kg heatCapacity = 4200 J/(kg*K) rise = 40 K power = 500 W energy := mass*heatCapacity*rise [J] duration := energy/power [s] check heating time budget: duration <= 600.0 s scenario alternative: mass = 0.8 kg