# Steady conduction # Scope: Steady one-dimensional slab conduction at constant conductivity. # Status: illustrative worked example; engineering review pending. # Inputs are example values. Checks are editable example requirements, not standards. conductivity = 0.2 W/(m*K) area = 1 m^2 thickness = 50 mm difference = 20 K resistance := thickness/(conductivity*area) [K/W] heat := difference/resistance [W] check heat loss budget: heat <= 100 W scenario alternative: conductivity = 0.16 W/(m*K)