# Buck-boost converter screening # Scope: Ideal inverting buck-boost output magnitude; CCM. # Status: illustrative worked example; engineering review pending. # Inputs are example values. Checks are editable example requirements, not standards. input = 12 V outputMagnitude = 18 V load = 1 A duty := outputMagnitude/(input+outputMagnitude) inputCurrent := outputMagnitude*load/input [A] check duty budget: duty <= 0.8 scenario alternative: input = 9.6 V