# Gas-charged accumulator sizing # Scope: Polytropic gas accumulator volume swing at absolute pressures. # Status: illustrative worked example; engineering review pending. # Inputs are example values. Checks are editable example requirements, not standards. gasVolume = 1 L precharge = 5 MPa lowPressure = 6 MPa highPressure = 10 MPa exponent = 1.4 lowGas := gasVolume*(precharge/lowPressure)^(1/exponent) [L] highGas := gasVolume*(precharge/highPressure)^(1/exponent) [L] delivery := lowGas-highGas [L] check delivery target: delivery >= 0.2 L scenario alternative: gasVolume = 0.8 L