# Molded-part cooling-time estimate # Scope: Reference-calibrated squared wall-thickness cooling scale; not a full transient thermal solve. # Status: illustrative worked example; engineering review pending. # Inputs are example values. Checks are editable example requirements, not standards. referenceTime = 20 s referenceThickness = 2 mm thickness = 3 mm duration := referenceTime*(thickness/referenceThickness)^2 [s] check cooling time budget: duration <= 60 s scenario alternative: referenceTime = 16 s