# Laminar capillary flow # Scope: Hagen-Poiseuille circular pipe, fully developed laminar Newtonian flow. # Status: illustrative worked example; engineering review pending. # Inputs are example values. Checks are editable example requirements, not standards. diameter = 5 mm length = 1 m viscosity = 0.001 Pa*s flow = 0.1 L/min density = 1000 kg/m^3 pressureDrop := 128*viscosity*length*flow/(pi*diameter^4) [Pa] reynolds := 4*density*flow/(pi*diameter*viscosity) check laminar applicability: reynolds < 2300 scenario alternative: diameter = 4 mm